AmpliVue HSV 1+2

The AmpliVue HSV 1+2 Assay is an in vitro diagnostic test for the qualitative detection and differentiation of Herpes simplex virus type 1 (HSV-1) and Herpes simplex virus type 2 (HSV-2) nucleic acids isolated from cutaneous and mucocutaneous lesions of symptomatic patients.

The assay consists of three major steps: (1) specimen preparation (one-step dilution), (2) isothermal Helicase-Dependent Amplification (HDA) of target amplicons specific to HSV-1 and HSV-2, and (3) detection of the amplified DNA by target-specific hybridization probes via a colorimetric reaction on a lateral-flow strip which is embedded in a self-contained disposable cassette to prevent amplicon contamination.

Specimen preparation involves a simple one step dilution in which specimens in viral transport medium are added to a dilution tube. The diluted sample is transferred into Reaction Tube containing lyophilized mix of HDA reagents including primers specific for the amplification of HSV-1 and HSV-2. Competitive amplification of the process control DNA takes place unless amplification inhibitory substances are present or the sample processing fails.

After completion of the HDA reaction, the Reaction Tube is transferred to a Cassette for rapid detection with the test result displayed as test and/or control lines in the window of the Cassette. The dual-labeled probe-amplicon hybrid is then detected by the lateral flow strip within the Cassette. The HSV-1 amplicon is captured at the T1-Line and HSV-2 amplicon is captured at the T2-Line, while the process control amplicon is captured at the C-Line. The Biotin in the amplicon-probe complexes captures the streptavidin-conjugated color particles for visualization and the molecular test result is shown as colored lines that are visually read.
 

Features & Benefits

   
Feature Benefit
Small, self-contained hand-held cassette

No isolation room needed

Convenient, easy-to-use, disposable device

HDA technology

Rapid method of nucleic acid amplification that does not require thermal cycler

Lyophilized Master Mix reagent

Easy-to-use format, just rehydrate with diluted sample.

Small easy-to-use heat blocks

Eliminates need for dedicated molecular space and costly capital equipment. Allows for testing in smaller labs.

CLIA moderately complex

Requires minimal training

Refrigerated storage

No freezer needed. 2°C to 8°C storage.

Long shelf life

24 months from date of manufacture

Room temperature set up

No ice or cooling block required

Product Specifications

Sample Type

Cutaneous and mucocutaneous lesion specimens from symptomatic patients

Time to results

Approximately 60 minutes

Reagent storage conditions

2°C to 8°C Dilution and Reaction Tubes; 2°C to 30°C Amplicon Cartridge and Detection Cassette

Controls storage conditions

2°C to 8°C

Sample preparation storage conditions

20°C to 25°C for 1 hour prior to testing; 2°C to 8°C for 8 hours; and 1 month at –20°C to –70°C

HSV-1 Sensitivity*

Cutaneous Lesions – 100% (95% CI 88.6% to 100%); Mucocutaneous Lesions – 94.9% (95% CI 90.3% to 97.4%)

HSV-1 Specificity*

Cutaneous Lesions – 97.1% (95% CI 94.6% to 98.5%); Mucocutaneous Lesions – 96.5% (95% CI 94.8% to 97.7%)

HSV-2 Sensitivity*

Cutaneous Lesions - 98.3% (95% CI 91.0% to 99.7%); Mucocutaneous Lesions - 97.4% (93.4% to 99.0%)

HSV-2 Specificity*

Cutaneous Lesions: 95.6% (95% CI 92.8% to 97.3%); Mucocutaneous Lesions: 95.8% (94.2% to 97.0%)

LOD*

HSV-1: 1.1 x 105 TCID50/mL; HSV-2: 1.1 x 104 TCID50/mL

*Refer to Package Insert for additional performance claims.

Ordering Information

     
Catalog Number Description Kit Size / Case Size
M210

Assay Kit

16 tests
M109

Quidel Molecular HSV 1+2 Control Set

1 mL

Product Documentation

PDF icon  Package Insert
PDF icon  Procedure Card
PDF icon  CLSI
PDF icon  SDS
PDF icon  FAQ
PDF icon  Quiz
PDF icon  Sales Sheet
PDF icon  Technical Bulletin - External QC
PDF icon  Technical Bulletin - Lysis and Amplification Blocks
PDF icon  Technical Bulletin - Decontamination and Contamination Prevention
PDF icon  Package Insert - Control Set
PDF icon  Instruction Manual - 64°C Amplification Block
PDF icon  Instruction Manual - 95°C Lysis Block
PDF icon  Package Insert - Spanish
PDF icon  Package Insert - French
温馨提示:不可用于临床治疗。

免责声明

本网页所展示的有关【AmpliVue HSV 1+2】的信息/图片/参数等由的会员【上海钰博生物科技有限公司 】提供,由【生物实验采购网】会员【上海钰博生物科技有限公司 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法 律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【AmpliVue HSV 1+2】有关的信息/图片/价格等及提供 【AmpliVue HSV 1+2】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电,我们将竭诚为您服务,感谢您对【生物实验采购网】的关注与支持!

网站首页 | 关于我们 | 联系方式 | 使用协议 | 版权隐私 | 网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报
 
免责声明:本站有部分内容来自互联网,如无意中侵犯了某个媒体 、公司 、企业或个人等的知识产权,请来电或致函告之,本网站将在规定时间内给予删除等相关处理。